# gln configuration file # # lines starting with # (like this one) are comments # lines starting with F0 or FR define global parameters # lines starting with F1 define the detector slot parameters # lines starting with F2 define the detector parameters # lines starting with F3 define the detector RTD/temp parameters # lines starting with F4 define the manifold parameters # # # ADC Panel conditioning circuit calibration 1.855 4.667 # # global parameters #F0 master_valve_num pres_adc pres_min pres_max F0 c3.6 c47.1 -300 330 # pressures in psi #FR min_range max_range (values outside this range means adc not connected?) FR 10 2450 # for temperature adcs #FV post-fill vent duration, in minutes (set to zero for no vent) FV 5 # disabled; usual enabled value = 10 # # # manifold/slot valve_num: # manifold 1: c0.1-c0.8 (i.e., 8 outlets per power strip) # manifold 2: c1.1-c1.8 # # slot parameters # valve_num is valve id for filling detector in this slot # olfo_adc is adc id for overflow sensor for filling detector in this slot # olfo_lim is adc value for liquid at overflow sensor #F1 slot_num man_num valve_num oflo_adc olflo_lim adc2K adc_offset # F1 1 1 c1.1 c21.1 46 1.855 4.667 F1 2 1 c1.2 c22.1 46 1.855 4.667 F1 3 1 c1.3 c23.1 46 1.855 4.667 F1 4 1 c1.4 c24.1 44 1.855 4.667 F1 5 1 c1.5 c25.1 43 1.855 4.667 F1 6 1 c1.6 c26.1 43 1.855 4.667 F1 7 2 c2.1 c27.1 43 1.855 4.667 F1 8 2 c2.2 c28.1 43 1.855 4.667 F1 9 2 c2.3 c29.1 44 1.855 4.667 F1 10 2 c2.4 c30.1 43 1.855 4.667 F1 11 2 c2.5 c31.1 43 1.855 4.667 F1 0 0 c3.1 c20.1 45 1.855 4.667 # # # # # detector parameters # slot_num is the slot where this detector is mounted, or -1 for not mounted # min_dur, max_dur are for duration in seconds # interval is fill interval in hours #F2 det_num slot_num min_dur max_dur interval F2 1 1 60 610 6.0 F2 2 2 60 460 8.0 F2 3 3 60 400 8.0 F2 4 4 60 400 8.0 F2 5 5 60 400 8.0 F2 6 6 60 400 4.0 F2 7 7 60 460 8.0 F2 8 8 60 400 8.0 F2 9 9 60 500 5.0 F2 10 10 60 400 8.0 F2 11 11 60 400 8.0 # # TANK + ROOM TEMP F2 0 0 60 10800 48.0 # # # detector RTD (temp) parameters # temp_adc is the adc id for the internal temperature of this detecor # max_temp is the max detector temp for a happy system, with no alarm # max_HV is the max detector temp for HV allowed on crystal # adc2K, adc_offset are adc-to-temp conversion parameters #F3 det_num temp_adc max_temp max_HV adc2K adc_offset # F3 1 c1.1 100 125 1.855 4.667 F3 2 c2.1 112 125 1.855 4.667 F3 3 c3.1 107 125 1.855 4.667 F3 4 c4.1 108 125 1.855 4.667 F3 5 c5.1 108 125 1.855 4.667 F3 6 c6.1 5000 5000 1.855 4.667 F3 7 c7.1 150 135 1.855 4.667 F3 8 c8.1 112 125 1.855 4.667 F3 9 c9.1 125 125 1.855 4.667 F3 10 c10.1 115 125 1.855 4.667 F3 11 c12.1 112 125 1.855 4.667 # ROOM TEMP F3 0 c0.1 306 306 1.855 4.667 # # # manifold parameters # valve_num is valve id for precooling this manifold # olfo_adc is adc id for overflow sensor for precooling this manifold # olfo_lim is adc value for liquid at overflow sensor # min_dur, max_dur are for duration in seconds # #F4 man_num valve_num oflo_adc olflo_lim max_dur adc2K adc_offset F4 0 c3.1 c20.1 3000 10 1.855 4.667 F4 1 c1.8 c41.1 50 360 1.855 4.667 F4 2 c2.8 c42.1 43 360 1.855 4.667